PRODUCT DETAILS
Specification: 60L
Dehumidification capacity: 60 liters per day
Rated power: 650w
Humidity control range: 10%-95%
Main material: Sheet metal
Rated voltage: 220V
Applicable area: 60-100 square meters
Air outlet: 400m/h
Overall dimensions (L*W*H) : 375*295*625mm
Drainage method: Direct drainage through hose
Air outlet method: Side air intake, rear air outlet, hot air
Weight: 28kgs
Protection function: Overload protection
Control methods: Key control, touch control
Warm reminder
When powering on, it is necessary to confirm the supply voltage and frequency, which should be consistent with the power supply required by the machine to avoid burning out the machine due to inconsistent power supply. The power supply must have a good grounding and leakage overload protection switch.
This machine must not be used for a long time in a high-dust environment; otherwise, it is prone to malfunction.
This machine must not be used in an environment with flammable, explosive or corrosive gases. (If used in such an environment, a dehumidifier with explosion-proof and anti-corrosion performance should be purchased.)
When the machine is in operation for a long time, the filter screen should be cleaned frequently. When the dust in the usage environment is large, it should be cleaned once every 3 to 5 days. At the same time, the dust adhering to the surface of the evaporator should be removed in a timely manner; otherwise, it will affect the service life of the machine. Please carry out regular maintenance.
When this machine is in operation, the air around the machine should be kept circulating. The distance between stacked items should be at least 1 meter. No items should be piled up at the air outlet, otherwise accidents are likely to occur.
When draining water, the position of the drainage pipe must not be higher than the machine's drainage outlet. If the drainage pipe is extended, a dedicated drainage pipe material should be used. The diameter of the drainage pipe must not be reduced to ensure smooth drainage; otherwise, it is easy to cause leakage.
Warning
The room area for the installation, operation and storage of the equipment should be greater than 50 square meters.
This machine uses an environmentally friendly refrigerant: R290
Installation Instructions for Water Pipes
1.This machine is equipped with two standard drainage methods: gravity drainage and pump drainage, which can be selected for use in different scenarios.
2. Gravity drainage: A wavy hose with an inner diameter of Φ16mm is provided with the machine. Remove the rubber plug of the gravity drainage outlet, insert one end of the water pipe into the gravity drainage outlet, and use a clamp to cover the connection between the water pipe and the gravity drainage to ensure that there is no leakage at the connection. Note that the water pipe must not be higher than the gravity drainage outlet. The water pipe should have a certain inclination and must not be bent to ensure smooth water flow.
3. Water pump drainage: A silicone hose with an inner diameter of Φ5mm is provided with the machine. Insert one end of the hose into the drainage port of the water pump and secure it tightly with a cable tie to ensure no leakage at the connection. The water pump drainage has a certain water pressure and can drain water over long distances. However, it is necessary to ensure that the drainage height does not exceed 5 meters. When laying the pipes, make sure that the water pipes are not folded; otherwise, it may cause leakage or burn out the water pump.
4. Note: If the user provides their own water pipes, please pay attention to the consistency of specifications.
5. Suggestion: If used at fixed points for a long time, the two drainage methods can be installed and used together to reduce drainage failures caused by long-term water quality issues.